NEN 1010 • NEN 3140 • Reporting

Testing & Inspection

Safer installations through NEN inspections. Compliant with NEN 1010 (design/commissioning) and NEN 3140 (in-service/periodic).

Licensed installer • VCA • Seal rights (Liander) • Last update: 19-10-2025

What do we inspect?

Distribution boards, protective devices (MCBs/RCBOs/RCDs), cabling, earthing/bonding, documentation (schematics/circuit schedule) and alignment with actual use. We assess electrical safety (shock/fire) and functional performance.

When to (re)inspect?

  • Commissioning or modification of an installation (NEN 1010)
  • Periodic in-service inspection (NEN 3140) — typically every 1–5 years
  • Change in use or load (e.g. EV charger, heat pump, PV)
  • Handover/tenant change or insurer/OSH requirement
  • After faults, thermal issues or consumer-unit upgrades

Our process

  • Scope & preparation (drawings, previous reports, operations)
  • Visual inspection (build, labelling, IP rating, penetrations, fire load)
  • Measurements & tests (insulation, continuity, loop impedance, RCD test, etc.)
  • Reporting with photos, readings and priorities (Pass/Fail)
  • Remediation advice and quote (optional); re-inspection after fix

Measurements & tests

  • Insulation resistance • PE continuity • Earth resistance
  • Fault loop impedance / PSCC • Polarity • Phase sequence
  • RCD/RCBO test (IΔn, trip time) • Voltage drop (where relevant)
  • Functional tests of protections/emergency systems • SPD check and, if applied, AFDD

Deliverables

  • PDF report with findings, photos and measurement records
  • Defect list with priority (safety/continuity/regulatory)
  • Concrete remediation plan • Re-inspection report after fixes

Quote checklist (useful information)

  • Site type (residential, commercial, industrial) and address
  • Number of distribution boards and main supply (1-/3-phase, fuse rating)
  • Approx. number of final circuits and special circuits (EV, PV, cooker/Perilex, heat pump)
  • Access windows / ability to isolate power
  • Available documentation (schematics, previous reports, circuit schedule)
  • Known issues/symptoms (RCD tripping, hotspots, etc.)

Wat klanten zeggen

“Netjes gewerkt en goed meegedacht. WiFi is nu overal stabiel.”
Fam. De Vries, Zwolle
“Site-survey en kanaalplan gedaan. Veel minder interferentie op kantoor.”
Bureau Nova, Lelystad
“Mesh goed ingesteld en bekabelde backhaul aangelegd. Snelheid verdubbeld.”
C. Willems, Harderwijk
“Gastnetwerk ingericht en AP-plaatsing geoptimaliseerd. Reviews verbeterd.”
B&B Orion, Deventer
“Dekking in kleedkamers en hal opgelost. Heldere rapportage.”
Gym XS, Apeldoorn
“Snel ingepland en een helder rapport. Storingen direct verholpen — top!”
Bedrijf Zeta, Apeldoorn
“Duidelijke uitleg, keuringsrapport met foto’s en prioriteiten. Aanrader.”
Studio Orion, Deventer
“Heldere offertes, geen verrassingen. Gewoon goed werk.”
Café Delta, Zutphen
“Extra eindgroep volgens NEN 1010 aangelegd. Strak en netjes.”
Fietsplein, Kampen
“Beproevingen en metingen professioneel uitgevoerd. Snelle oplevering.”
Werkplaats 12, Zwolle
VCA-gecertificeerd NEN 1010 / 3140 Zegelrecht (Liander-gebied)